Test ID: AH50

Test Name: Alternative Complement Pathway, Hemolytic

Test Codes


  • EPIC Code: LAB3103
  • Exsera Order Code: AH50
  • CPT Code: 86161

Specimen Requirements


Specimen Type: Serum

Collection Tube: Red or Tiger Top

Collection Instructions:  Allow collected blood to clot for 20-60 minutes before centrifuging. Then transfer to cryogenic tubes and aliquot as necessary before freezing and storing tubes at -80C within 2 hours of collection.

Volume Required: ~400 mcL  

Storage/Transport Temperature: Frozen @ -80C

Stability: 1 year minimum while stored @ -80C from date of draw

Unacceptable Conditions: Severely Hemolyzed or thawed/non-frozen samples 

Ordering Recommendation


Reference Interval


Normal Human: 76 - 176 U/mL

ULOQ/ALQ: N/A

LLOQ/BLQ: <27 U/mL

Test Classification


This test is a laboratory developed test per the US Food and Drug Administratio's guidelines and is used per manufacturer's instructions and per Exsera's SOPs. Performance characteristics were verified by Exsera in a manner consistent with CAP/CLIA requirements.

Methodology


Hemolytic (In house)

Patient Reporting


Standard: 7-14 Days

Aliases


AH50, Complement Alternative Pathway Function

Additional Notes


Diagnostic samples held for 1 month before disposal of remaining sample